Please use this identifier to cite or link to this item: http://13.232.72.61:8080/jspui/handle/123456789/1004
Title: Bubble Size Measurement and Error Analysis for a Gas Liquid Ejector
Authors: Suneetha, T. B.
Raghuram, P. T.
Keywords: Biotechnology
Bubble size
Gas liquid ejector
Error analysis
Prolate ellipsoid
Issue Date: Nov-2012
Publisher: Indian Journal of Chemical Technology.
Citation: Suneetha, T. B., & Raghuram, P. T. (2012). Bubble size measurement and error analysis in a gas liquid ejector. Indian Journal of Chemical Technology, 19(6), 442-446.
Abstract: Bubble size in a gas liquid ejector has been measured using the image technique and analysed for estimation of Sauter mean diameter. The individual bubble diameter is estimated by considering the two dimensional contour of the ellipse, for the actual three dimensional ellipsoid in the system by equating the volume of the ellipsoid to that of the sphere. It is observed that the bubbles are of oblate and prolate shaped ellipsoid in this air water system. The bubble diameter is calculated based on this concept and the Sauter mean diameter is estimated. The error between these considerations is reported. The bubble size at different locations from the nozzle of the ejector is presented along with their percentage error which is around 18%.
URI: http://13.232.72.61:8080/jspui/handle/123456789/1004
ISSN: e-0975-0991
p-0971-457X
Appears in Collections:Faculty Publications

Files in This Item:
File Description SizeFormat 
Bubble Size Measurement and Error Analysis for a gas liquid ejector.pdf87.42 kBAdobe PDFView/Open